Spindle Replacement

Guide · Homeowners and Landlords · 4 min read · Updated 17 November 2026

Stair Spindle Gap Regulations UK: The 100 mm Rule Explained

Short answer

Under Approved Document K, guarding on stairs and landings should not let a 100 mm sphere pass through any opening, so the clear gap between spindles must be less than 100 mm. In a single-family home, guarding must be at least 900 mm high. Existing stairs do not have to be upgraded automatically, but new or replacement balustrades should meet these figures.

Stair Spindle Gap Regulations UK: The 100 mm Rule Explained

The 100 mm sphere rule

Approved Document K, which gives practical guidance on meeting the Building Regulations for stairs in England, says that guarding on stairs and landings in buildings likely to be used by children under five should not allow a 100 mm sphere to pass through any opening. Homes fall into that category. The figure was chosen because a gap of 100 mm or more could let a small child's head or body pass through.

In practice, joiners set spindles so the clear gap between them is less than 100 mm, often around 90 to 95 mm to allow for slight variation. The gap is measured between the spindles, not from centre to centre. The same rule applies to the triangle formed under the baserail on some stairs, and to gaps between treads on open-riser stairs.

  • Measure the clear gap between spindles, not centre to centre
  • Aim for a gap comfortably under 100 mm
  • Check the gap under the baserail and at the newels
  • Check gaps on open risers as well as the balustrade

Guarding height

For a single-family dwelling, Approved Document K says guarding on stairs and landings should be at least 900 mm high. On the stair, height is measured vertically from the pitch line, the imaginary line joining the tread nosings. On landings, it is measured from the floor. Many older stairs, especially Victorian and Edwardian ones, have landing balustrades lower than this, which is a common reason to raise handrails during a renovation.

Handrails are slightly different from guarding. A handrail is what you hold; guarding is what stops you falling. On many stairs the handrail on top of the spindles does both jobs, so the height matters for both reasons.

Guarding also needs to be strong. A balustrade must resist people leaning on it or falling against it, so newels must be securely fixed and handrails firmly attached. A balustrade that meets the height and gap rules but wobbles when pushed is still unsafe.

RuleFigure in a single-family homeWhere it applies
Maximum opening in guarding100 mm sphere must not passBetween spindles, under baserails, open risers
Minimum guarding height on stairs900 mmMeasured from the pitch line
Minimum guarding height on landings900 mmMeasured from the floor
Handrail height on stairs900–1,000 mmMeasured from the pitch line

Do existing stairs have to comply?

Building Regulations apply when building work is carried out, not retrospectively to every existing staircase. An older stair with wider gaps or a lower balustrade is not automatically illegal just because it predates current guidance. Replacing a single broken spindle with a matching one is generally treated as a repair. However, when you replace the balustrade, re-spindle the whole flight or build a new staircase, it is sensible, and expected, for the new work to meet current guidance.

If you are unsure whether your planned work needs Building Control involvement, contact your local authority Building Control team, who can advise on your specific situation.

If you are selling, a buyer's surveyor may note wide gaps or low balustrades as a safety point. That does not stop a sale, but it can prompt questions, so upgrading at the same time as other work can be worthwhile.

Landlords and rented homes

Landlords in England have duties around hazards in rented homes. The Housing Health and Safety Rating System, used by councils to assess housing conditions, includes falling on stairs as one of its hazards, and wide gaps or low, loose balustrades can contribute to that. Councils can require landlords to deal with serious hazards. Bringing spindle gaps and balustrade heights up to current guidance is a practical way to reduce risk, particularly in family lets and houses in multiple occupation.

For any rental property, it is also worth checking that the handrail and spindles are firmly fixed, as a loose balustrade is a hazard regardless of its gaps.

Listed buildings and Scotland

In a listed building, altering spindles, handrails or staircases can require listed building consent from the local planning authority, even for like-for-like repairs. Original balustrades are often part of what makes the building special, so councils may prefer discreet safety measures, such as fitting a clear panel behind the original spindles, rather than replacing them. Always check before starting.

In Scotland, stairs are covered by the Scottish Building Standards rather than Approved Document K. The principles are similar, but you should check current Scottish guidance and with the local authority for new or altered stairs.

Closing gaps on an existing stair

If your spindles are too far apart, there are several options. A joiner can add extra spindles between the existing ones, provided there is space on the rails and they match. Alternatively, the whole flight can be re-spindled at closer spacing. For period stairs where the originals should stay, clear polycarbonate or toughened glass panels can be fixed discreetly behind the balustrade. Low landing balustrades can be raised with a new handrail fixed above the old one or by extending newels. We arrange these safety upgrades through vetted local joiners who will measure the stair and explain the options.

Questions people also ask

What is the maximum gap between stair spindles in the UK?

Approved Document K says a 100 mm sphere should not pass through any opening in the guarding of a stair or landing in a home. In practice, the clear gap between spindles must be less than 100 mm, and joiners usually aim for around 90 to 95 mm.

How high should a landing balustrade be?

In a single-family dwelling, guarding on landings should be at least 900 mm high, measured from the floor, under Approved Document K. Many older homes have lower landing balustrades, which can be raised with a new handrail or extended newels during a renovation.

Do I have to replace old spindles that are too far apart?

Not automatically, because Building Regulations apply when work is done rather than retrospectively. But wide gaps are a real risk for small children, and if you re-spindle or replace the balustrade, the new work should meet current guidance. Landlords should also consider their duties around stair hazards.

Written and checked by the Spindle Replacement team. Read our editorial policy.

Get a free spindle replacement quote